Shutdown Circuit (SDC) & Brake System Plausibility Device (BSPD)
ID: ELE-SDC-001 | Regolamento: FSG Rules EV5.1 & EV2.4
Topologia del Circuito SDC
Circuito cablato in serie alimentato a 12 VDC nominali che pilota le bobine degli Accumulator Isolation Relays (AIR):
- Cockpit Emergency Stop Switch
- Left & Right Master Emergency Stops
- Inertia Switch (Sensore dβurto crash)
- Brake Over-Travel Switch (BOTS)
- IMD (Insulation Monitoring Device Bender A-ISOMETER)
- BMS Master Fault Line
- BSPD (Dispositivo non programmabile analogico)